B.A.S Cable Fire Alarm and Instrumentation Cable |
| |
| (Part No.) |
Description |
 |
| *8760 |
|
| Paired- Audio, Control and Instrumentation Cable
|
| Number of Pairs: 1 |
| Total Number of Conductors: 2 |
| AWG: 18 |
| Stranding: 16x30 |
| Conductor Material: TC - Tinned Copper |
| Insulation Material: PE - Polyethylene |
| Outer Shield Material Trade Name: Beldfoil® |
| Outer Shield Material: Aluminum Foil-Polyester Tape w/Shorting Fold |
| Outer Jacket Material: PVC - Polyvinyl Chloride |
| Plenum (Y/N): N |
| Plenum Number: 88760,87760 or 82760 |
| Applications: Audio, Control and Instrumentation Cable, Industrial Data, Interconnect, Analog Audio Cables, Single Pair |
|
|
| (Part No.) |
Description |
 |
| *8761 |
|
| Paired- Audio, Control and Instrumentation Cable |
| Number of Pairs: 1 |
| Total Number of Conductors: 2 |
| AWG: 22 |
| Stranding: 7x30 |
| Conductor Material: TC - Tinned Copper |
| Insulation Material: PE - Polyethylene |
| Outer Shield Material Trade Name: Beldfoil® (Z-Fold®) |
| Outer Shield Material: Aluminum Foil-Polyester Tape |
| Outer Jacket Material: PVC - Polyvinyl Chloride |
| Plenum (Y/N): N |
| Plenum Number: 88761,87761,82761 |
| Applications: Audio, Control and Instrumentation Cable, Analog Audio Cables, Single Pair |
|
|
| (Part No.) |
Description |
 |
| *8723 |
|
| Paired- Audio, Control and Instrumentation Cable
|
| Number of Pairs: 2 |
| Total Number of Conductors: 4 |
| AWG: 22 |
| Stranding: 7x30 |
| Conductor Material: TC - Tinned Copper |
| Insulation Material: PP - Polypropylene |
| Inner Shield Material: Aluminum Foil-Polyester Tape |
| Outer Shield Material: Unshielded |
| Outer Jacket Material: PVC - Polyvinyl Chloride |
| Plenum (Y/N): N |
| Plenum Number: 82723,87723,88723 |
| Applications: Audio Interconnect, Audio, Control and Instrumentation Cable, Analog Audio Cables, Double Pair, Industrial Data, Interconnect |
|
|
|
| |
Fire Alarm Cables
|
| |
| (Part No.) |
Description |
 |
| *YM46938 |
|
| Non-Paired- Fire Alarm Cable
|
| Number of Conductors: 2 |
| Total Number of Conductors: 2 |
| AWG: 16 |
| Stranding: Solid |
| Conductor Material: BC - Bare Copper |
| Insulation Material: PVC - Polyvinyl Chloride |
| Outer Shield Material Trade Name: Beldfoil® (Z-Fold®) |
| Outer Shield Material: Aluminum Foil-Polyester Tape |
| Outer Jacket Material: PVC - Polyvinyl Chloride |
| Plenum (Y/N): N |
| Applications: Fire Alarm Cables, Power-Limited Fire Protective Signaling Circuit Cables |
|
|
| (Part No.) |
Description |
 |
| *YM46939 |
|
| Non-Paired- Fire Alarm Cable |
| Number of Conductors: 2 |
| Total Number of Conductors: 2 |
| AWG: 14 |
| Stranding: Solid |
| Conductor Material: BC - Bare Copper |
| Insulation Material: PVC - Polyvinyl Chloride |
| Outer Shield Material Trade Name: Beldfoil® (Z-Fold®) |
| Outer Shield Material: Aluminum Foil-Polyester Tape |
| Outer Jacket Material: PVC - Polyvinyl Chloride |
| Plenum (Y/N): N |
| Applications: Fire Alarm Cables, Power-Limited Fire Protective Signaling Circuit Cables |
|
|
| (Part No.) |
Description |
 |
| *5120UL |
|
| Non-Paired- New Generation® |
| Suitable Applications: Fire Protections, Alarm, Signal, Monitor/Detection, Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits |
| Number of Conductors: 2 |
| Total Number of Conductors: 2 |
| AWG: 14 |
| Stranding: Solid |
| Conductor Material: BC - Bare Copper |
| Insulation Material: PVC - Polyvinyl Chloride |
| Outer Shield Material: Unshielded |
| Outer Jacket Material: PVC - Polyvinyl Chloride |
| Plenum (Y/N): N |
| Plenum Number: 6120UL |
| Applications: Fire Alarm Cables, FPLR |
|
|
|
| |
| * Normal Stock Item |
| Standard Packing : 305 M. or 1,000 Ft./Rool +/-10% Tolerance. |
| |
 |
 |
| |
|
|
|
|
|